Power Units > Dry Power Unit

         
 

Standard Equipment

  • IMO pump
  • Imperial Motors - 120 Starts Per Hour Available (Up to 75 HP)
  • Maxton Valve
  • Maximum of 100 HP Per Motor, Up to 2 Motors Per Tank
  • Oil Level Sight Gauge
  • Drip Pan Included with Each Pump and Motor Assembly
  • Isolation Between Pump/Motor Assembly and Main Framework
  • Victaulic Couplings
  • Anchoring Holes for the Frame to Floor
  • MEI Oil Cooler Ready
  • Junction Box
  • Seismic Compliant
  • Unit can be Disassembled to Fit Through Small Openings

Standard Options

  • Compact Silencer with Pneumatic Noise Suppression
  • Tank Heater
  • Loadweigh Switch
  • Viscosity Temperature Switch
  • Pressure Gauge (mounted on valve)
  • Low Oil Level Switch (in tank)
  • Low Pressure Switch (required if jack head is above power unit)
  • Oil Cooler
  • Oil Return Pump
  • Vent/Fill Strainer
  • Down Speed Regulated Valve
  • Vegetable Based Oil Provisions
  • 80 SPH
  • Frame to Floor Isolation
  • Drain Valve
  • Over Flow connection
  • Chamber Silencer
  • Panels with Insulation (panels not shown on image)

Reliability
Each unit is pressure-tested prior to shipment.

 

 Printable Brochure / Quote Request Form

 
       
   
 

Standard Tank Sizes

Model Width Depth Height Motors Transferalbe Oil
DS-72 54" 34" 72" Single 72 gal.
DS-72 Tall 54" 34" 78" Single 114 gal.
DS-96 62" 40" 72" Single 96 gal.
DS-96 Tall 62" 40" 78" Single 154 gal.
DS-110 62" 46" 72" Single 110 gal.
DS-110 Tall 62" 46" 78" Single 177 gal.
DT-192 117-¾" 40" 72" Single or Tandem 192 gal.
DT-192 Tall 117-¾" 40" 78" Single or Tandem 308 gal.
DT-221 117-¾" 46" 72" Single or Tandem 221 gal.
DT-221Tall 117-¾" 46" 78" Single or Tandem 335 gal.
   
 

Electrical Data for Hydraulic 3 Phase Motors in a Dry Mount Power Unit

HP VOLT Full Load Amps Locked Rotor Amps
15 200, 208 46.2 279
220, 230, 240 42 242
440, 460, 480 21 121
20 200, 208 60 261
220, 230, 240 52 224
440, 460, 480 26 112
25 200, 208 73 331
220, 230, 240 63 290
440, 460, 480 32 145
30 200, 208 83 419
220, 230, 240 72 351
440, 460, 480 36 175
40 200, 208 109 495
220, 230, 240 94 424
440, 460, 480 47 212
50 200, 208 133 667
220, 230, 240 116 562
440, 460, 480 58 281
 
 
HP VOLT Full Load Amps Locked Rotor Amps
60 200, 208 160 833
220, 230, 240 140 724
440, 460, 480 70 362
75 220, 230, 240 174 800
440, 460, 480 87 400
100 230 230 1004
460 115 502
  • Values shown are based on one manufacturer's standard. Values may vary from manufacturer to manufacturer and with motor design.
  • Locked Rotor AMPS are given for across the line starting. Starting AMPS are .33 times Locked Rotor AMPS when starting on Wye Start - Delta Run.
  • To calculate approximate HP required:

This calculation is based on Adjacent Machine Room.
Contact a Salesperson for Remote Machine Room calculations.
(507) 245-3060
(507) 245-3275