Passenger Elevators – Standard Specifications (Low Capacity)
Cap. (lbs) Platform
Platform Width x Platform Depth
Hoistway
Hoistway Width x Hoistway Depth
Front (F) Rear (R) Laminate Clear Inside W x D Door Type Door Width See Entrance Details for Rough Openings Max Speed FPM

Elevation & Plan View Drawings

2100 6'-0" x 5'-1"

7'-10" x 5'-9"

F
5'-9" x 4'-3 ½"
1-SP
3'-0"
350
DWG File PDF File
2100 6'-0" x 5'-8"

8'-2" x 6'-8 ½"

F/R
5'-9" x 4'-3 ½"
1-SP
3'-0"
350
DWG File PDF File
2500 7'-0" x 5'-1"

8'-10" x 5'-9"

F
6'-9" x 4'-3 ½"
1-SP
3'-6"
350
DWG File PDF File
2500 7'-0" x 5'-8"

9'-2" x 6'-8 ½"

F/R
6'-9" x 4'-3 ½"
1-SP
3'-6"
350
DWG File PDF File
3000 7'-0" x 5'-6"

8'-10" x 6'-2"

F
6'-9" x 4'-8 ½"
1-SP
3'-6"
350
DWG File PDF File
3000 7'-0" x 6'-1"

9'-2" x 7'-1 ½"

F/R
6'-9" x 4'-8 ½"
1-SP
3'-6"
350
DWG File PDF File
3500 7'-0" x 6'-2"

8'-10" x 6'-10"

F
6'-9" x 5'-4 ½"
1-SP
3'-6"
350
DWG File PDF File
3500 7'-0" x 6'-9"

8'-10" x 7'-9 ½"

F/R
6'-9" x 5'-4 ½"
1-SP
3'-6"
350
DWG File PDF File
4000 8'-0" x 6'-2"

9'-10" x 6'-10"

F
7'-9" x 5'-4 ½"
1-SP
4'-0"
350
DWG File PDF File
4000 8'-0" x 6'-8"

9'-10" x 7'-8 ½"

F/R
7'-9" x 5'-3 ½"
1-SP
4'-0"
350
DWG File PDF File
Pit Depth * Pit Depth = 5'-2" • Overhead * Minimum Overhead = 16'-0" • Cab Height = 8'-0" • For seismic applications add 3" to hoistway width
 
Hospital Elevators – Standard Specifications
Cap. (lbs) Platform
Platform Width x Platform Depth
Hoistway
Hoistway Width x Hoistway Depth
* Min Overhead Overhead Front (F) Rear (R) Laminate Clear Inside W x D Door Type Door Width
See Entrance Details for Rough Openings
Max Speed FPM

Elevation & Plan View Drawings

3500H 5'-4" x 8'-4" 7'-2" x 9'-2"

16'-0"

F
5'-1" x 7'-5"
2-SP
3'-6"
350
DWG File PDF File
3500H 5'-4" x 9'-0 ½" 7'-2" x 10'-4"

16'-0"

F/R
5'-1" x 7'-5"
2-SP
3'-6"
350
DWG File PDF File
4000H 6'-0" x 8'-5" 7'-10" x 9'-3"

16'-0"

F
5'-9" x 7'-6"
2-SP
4'-0"
350
DWG File PDF File
4000H 6'-0" x 9'-1 ½" 7'-10" x 10'-5"

16'-0"

F/R
5'-9" x 7'-6"
2-SP
4'-0"
350
DWG File PDF File
4500H 6'-0" x 9'-2" 7'-10" x 10'-0"

16'-0"

F
5'-9" x 8'-3"
2-SP
4'-0"
350
DWG File PDF File
4500H 6'-0" x 9'-10 ½" 7'-10" x 11'-2"

16'-0"

F/R
5'-9" x 8'-3"
2-SP
4'-0"
350
DWG File PDF File
5000H 6'-0" x 9'-7 ½" 7'-10" x 10'-5 ½"

16'-6"

F
5'-9" x 8'-8"
2-SP
4'-0"
350
DWG File PDF File
5000H 6'-0" x 10'-3 ½" 7'-10" x 11'-7"

16'-6"

F/R
5'-9" x 8'-8"
2-SP
4'-0"
350
DWG File PDF File
Pit Depth * Pit Depth = 5'-2" • Cab Height = 8'-0" • For seismic applications add 3" to hoistway width
 
Passenger Elevators – Standard Specifications (High Capacity)
Cap. (lbs) Platform
Platform Width x Platform Depth
Hoistway
Hoistway Width x Hoistway Depth
* Min.
Pit Depth
Pit Depth
* Min. Overhead Overhead Front (F) Rear (R) Laminate Clear Inside W x D Door Width
See Entrance Details for Rough Openings
Max Speed FPM

Elevation & Plan View Drawings

6000 7'-0" x 8'-6"

8'-10" x 9'-4"

5"-2"

16'-6"

F
6'-9" x 7'-7"
4'-0"
350
DWG File PDF File
6000 7'-0" x 9'-2 ½"

8'-10" x 10'-6"

5"-2"

16'-6"

F/R
6'-9" x 7'-7"
4'-0"
350
DWG File PDF File
8000 8'-4" x 10'-0"

10'-2" x 10'-8 ½"

5"-2"

16'-6"

F
8'-1" x 9'-2 ½"
4'-0"
350
DWG File PDF File
8000 8'-4" x 10'-8 ½"

10'-2" x 11'-9"

5"-2"

16'-6"

F/R
8'-1" x 9'-4"
4'-0"
350
DWG File PDF File
10000 8'-4" x 11'-8 ½"

10'-8" x 12'-5"

6'-0"

16'-6"

F
8'-1" x 10'-11"
4'-6"
225
DWG File PDF File
10000 8'-4" x 12'-5"

10'-8" x 13'-5 ½"

6'-0"

16'-6"

F/R
8'-1" x 11'-0 ½"
4'-6"
225
DWG File PDF File
12000 10'-3" x 11'-6"

12'-7 ½" x 12'-2 ½"

6'-0"

16'-6"

F
10'-1" x 10'-8 ½"
5'-0"
200
DWG File PDF File
12000 10'-3" x 12'-0"

12'-7 ½" x 13'-0 ½"

6'-0"

16'-6"

F/R
10'-1" x 10'-7 ½"
5'-0"
200
DWG File PDF File
15000 12'-0" x 11'-6"

14'-6" x 12'-2 ½"

6'-0"

17'-0"

F
11'-9" x 10'-8 ½"
6'-0"
150
DWG File PDF File
15000 12'-0" x 12'-1 ½"

14'-6" x 13'-2"

6'-0"

17'-0"

F/R
11'-9" x 10'-9"
6'-0"
150
DWG File PDF File
Door Type = 2-SP • Cab Height = 8'-0" • For seismic applications add 3" to hoistway width
       
* Speeds exceeding 200 FPM require additional overhead and pit depth. Increase the pit depth and overhead by the amount listed below if the speed exceeds 200 fpm.
Minimum overhead and pit depth are based on the use of spring buffers for 200 fpm and less. Add 5" to overhead and pit depth if oil buffers are required.
Speed Overhead Pit
225 FPM 6" 5"
250 FPM 7" 5"
300 FPM 8" 5"
350 FPM 10" 6"

*To allow for variations in cab designs, an increase in the maximum inside net platform area not exceeding 5%, shall be permitted for the various rated loads.

GENERAL NOTE:

    1 lb. = 0.454 kg                  1ft2 = 9.29 E-2m2

APPROXIMATE CLEAR INSIDE DIMENSIONS OF CAB:

WIDTH = Platform less 4" Returnable Panel, Platform less 3" Laminate

DEPTH =
Single Opening
       With Single Slide or Center Parting Doors
       .......Platform less 9 ½" Laminate, Platform less 10" Returnable Panel
       With Two Speed Doors
       .......Platform less 11" Laminate, Platform less 11 ½" Returnable Panel

Double Opening
        With Single Slide or Center Parting Doors
       .......Platform less 16 ½" Laminate or Returnable Panel

    With Two Speed Doors
    ....Platform less 19 ½" Laminate or Returnable Panel

 

Notes:

  • MEI can provide Standard pre-engineered sizes as detailed as well as Non-Standard or Custom sizes. Please consult your MEI representative.
  • See entrance details for sill recess and entrance wall requirements.
  • Adequate supports for rail fastening are required per layout drawing. Inserts must be installed in block or brick walls. Block must be filled with mortar around inserts to provide rigid support. NOTE: per rail force shown on layout drawing.
  • Wood and steel/frame walls require suitable header support with inserts at each rail bracket location. NOTE: per rail force shown on layout drawing
 

Maximum* Inside Net Platform Areas for the Various Rated Loads

Rated Load, lb.

Inside Net Platform Area, ft2

2,100

24.2

2,500

29.1

3,000

33.7

3,500

38.0

4,000

42.2

4,500

46.2

5,000

50.0

6,000

57.7

8,000

72.9

10,000

88.0

12,000

103.0

15,000

125.1