Passenger Elevators > Cantilever Roped Hydraulic, Rear Slung

         
 
Single Opening (F)
 
Printable Brochure
 
       
   

= Platform Width
= Platform Depth
= Hoistway Width
= Hoistway Depth
= Clear Door Opening
= Overhead
= Pit Depth
= Platform to Wall

 

 
       
Download Written Specifications
Microsoft Word File PDF File 2000-4500 lbs.
 
 
Do not use hoistway dimensions for construction purposes. Different code year adoptions and local code variations may affect the hoistway size. Verify all dimensions with MEI prior to construction.
Passenger Elevators – Standard Specifications (Low Capacity)
Cap. Platform
Platform Width x Platform Depth
Hoistway
Hoistway Width x Hoistway Depth
Platform to Wall
Platform To Wall, Jack Side
Front (F) Rear (R) Laminate Clear Inside W x D Door Type Door Width
See Entrance Details for Rough Openings

Elevation & Plan View Drawings

2100

6'-0" x 5'-1"

7'-4" x 7'-3 ¼"
20"
F
5'-9" x 4'-3 ½"
1-SP
3'-0"
DWG File PDF File
2500

7'-0" x 5'-1"

8'-4" x 7'-3 ¼"
20"
F
6'-9" x 4'-3 ½"
1-SP
3'-6"
DWG File PDF File
3000

7'-0" x 5'-6"

8'-4" x 7'-8 ¼"
20"
F
6'-9" x 4'-8 ½"
1-SP
3'-6"
DWG File PDF File
3500

7'-0" x 6'-2"

8'-4" x 8'-4 ¼"
20"
F
6'-9" x 5'-4 ½"
1-SP
3'-6"
DWG File PDF File
4000

8'-0" x 6'-2"

9'-4" x 8'-5 ¾"
20"
F
7'-9" x 5'-3"
2-SP
4'-0"
DWG File PDF File

Pit Depth Pit Depth = 4'-0" • Overhead Minimum Overhead = 12'-0" • Cab Height = 8'-0"

 
 

Notes:

  • MEI can provide Standard pre-engineered sizes as detailed as well as Non-Standard or Custom sizes. Please consult your MEI representative.
  • Adequate supports for rail fastening are required per layout drawing. Inserts must be installed in block or brick walls. Block must be filled with mortar around inserts to provide rigid support. NOTE: per rail force shown on layout drawing.
  • Wood and steel/frame walls require suitable header support with inserts at each rail bracket location. NOTE: per rail force shown on layout drawing

*To allow for variations in cab designs, an increase in the maximum inside net platform area not exceeding 5%, shall be permitted for the various rated loads.

GENERAL NOTE:

    1 lb. = 0.454 kg                  1ft2 = 9.29 E-2m2

APPROXIMATE CLEAR INSIDE DIMENSIONS OF CAB:

WIDTH = Platform less 4" Returnable Panel, Platform less 3" Laminate

DEPTH =
Single Opening
       With Single Slide or Center Parting Doors
       .......Platform less 9 ½" Laminate, Platform less 10" Returnable Panel
       With Two Speed Doors
       .......Platform less 11" Laminate, Platform less 11 ½" Returnable Panel

Double Opening
        With Single Slide or Center Parting Doors
       .......Platform less 16 ½" Laminate or Returnable Panel

    With Two Speed Doors
    ....Platform less 19 ½" Laminate or Returnable Panel

Maximum* Inside Net Platform Areas for the Various Rated Loads

Rated Load, lb.

Inside Net Platform Area, ft2

2,100

24.2

2,500

29.1

3,000

33.7

3,500

38.0

4,000

42.2

4,500

46.2

 
 

Notes:

  • Hoistway dimensions based on maximum car speed of 150 FPM. Consult your MEI representative for speeds exceeding 150 FPM.
  • Total Travel = Maximum travel of 90' – 115'. Based on capacity.
  • Pit depth and overhead clearance are in accordance with ANSI code requirements. Local codes may vary these requirements. A pit ladder (by others) is required.
  • ANSI code requires that hoistways of elevators shall be provided with means to prevent the accumulation of smoke and hot gases in case of fire as required by the building code.
  • A 115 VAC GFI outlet and lights are required in the pit, and separate 115 VAC circuit to the elevator controller (by others).
  • Hoistway walls must support anchor forces. Forces to be specified by MEI on elevator layout drawing based on specific design conditions.
  • Pit floor must be adequately reinforced to transmit jack, buffer, and safety setting forces. Forces to be specified by MEI on elevator layout drawing based on specific design conditions.
  • Only elevator related equipment allowed in hoistway or equipment room.
  • All elevators require heat/smoke sensors (by others) at each floor and associated elevator machine room with wires returned to elevator control panel in machine room. (Verify with local code.)
  • Duties shown will meet general demands of most hospitals and institutions. Local codes and governing agencies may require special sizes.
  • ANSI code requires a locked governor access door at top of hoistway. This door (by others) is maximum size of 24" x 24" and must be accessible within the building or from the roof. The governor access door needs the same fire rating as the hoistway walls